Offshore MagazinePennWell Petroleum Group
PUBLICATIONS EVENTS RESOURCE CENTER BOOKSTORE FINANCIAL PRODUCTS CLASSIFIEDS INDUSTRY JOBS SUBSCRIBE MEDIA KIT
SUBSCRIBE magazines | e-newsletters
| advanced
site map | about 



Upcoming Events
January 2009
January 11-15
Petrotech International Oil & Gas Conference & Exhibition

New Delhi
India
Phone: +91 11 2436 4055
Fax: +91 11 2436 0872
Email
Website

January 14
Expandable Technology Oil & Gas Conference

Abu Dhabi
United Arab Emirates
Phone: +44 (0) 1483 598000
Email
Website

January 19-21
SPE Hydraulic Fracturing Technology Conference

The Woodlands, TX 
United States
Phone: 972 952 9393
Fax: 972 952 9435
Email
Website

January 19-21
World Future Energy Summit

Abu Dhabi
United Arab Emirates
Phone: +971 2 444 6011
Fax: +971 2 444 3987
Email
Website

January 19-21
Pipeline Rehabilitation & Maintenance Conference

Manama
Bahrain
Phone: 918 831 9160
Fax: 918 831 9161
Email
Website

January 19-21
Oil & Gas Maintenance Technology Conference & Exhibition

Manama
Bahrain
Phone: 918 831 9160
Fax: 918 831 9161
Email
Website

January 19-23
API Exploration & Production Winter Standards Meeting

San Antonio, TX 
United States
Phone: 202 682 8000
Fax: 202 682 8222
Website

January 21-23
API/AGA Oil & Gas Pipeline Welding Practices Conference

San Antonio, TX 
United States
Phone: 202 682 8000
Fax: 202 682 8222
Website


All Events




MARKETS
 Market Summary
 OGJ 200
 World Markets
 Oil / Energy Sector
 Major Indices
 Market Movers
 Currencies
 A-Z Stock Listing
 CEO Wealthmeter

MARKET WATCH: Oil price rises amid geopolitical tensions (Oil & Gas Journal, January 5, 2009, 11:25 AM)

| Add RSS Feed

Sensors monitor subsea component performance, pipeline deviations

Bjørge’s Naxys technology for subsea leak detection and condition monitoring is finding acceptance in the Norwegian sector. Development of this technology started around 10 years ago, according to managing director, Cato Bjelland. Naxys is named after the company that first developed it, which was acquired by Bjørge in 2005.

The product portfolio consists primarily of monitoring systems using acoustic and electro-magnetic sensors. The initial development was an acoustic leak detector. When a leak develops, a stream of fluid is created. This leads to pressure fluctuations that generate an acoustic field which propagates in the water and can be detected by a hydrophone.


A Naxys sensor package prepared for installation on the Tordis subsea separation station.

By using hydrophones and some local analytical capability, the direction from which the sound is coming can be identified. This is indicated by dividing the area around the sensor package into sectors of 20º.

The same sensors can be used for online monitoring of subsea equipment such as pumps which generate an acoustic field as they vibrate. This field is converted by the Naxys software into a frequency spectrum. Once the baseline pattern of the frequency spectrum associated with normal functioning has been identified, departures from normal functioning can be detected as deviations.

The technology also includes electro-magnetic antennas. These sense the electric field generated by electric equipment such as a motor driving a pump. Analysis of the readings makes it possible to identify patterns of normal functioning and also deviations.

More information can be generated by combining the acoustic and electro-magnetic data, says Bjelland. In the case of an electric motor, for example, an increase in the slippage factor may indicate malfunction.

Data analysis is in real-time by software installed in the Naxys module. The signals are transformed from time to frequency domain by a Fourier transformer. Analysis of the spectrum can be made the basis for intelligent decisions, such as sounding an alarm or triggering an automatic shutdown in the event of patterns indicating a malfunction or accident.

When the limit of the system’s memory has been reached, the accumulated data has to be transmitted to the surface. This may be either through a dedicated fiber-optic cable or via a connection to the subsea control pod and then through the existing communication system.

As seabed-to-surface communications capacity grows, driven in part by the need for systems like Naxys, the growing volume of information can become the basis for expanded functions, says Bjelland.

Leak test

Naxys systems for both leak detection and condition monitoring are on StatoilHydro’s Tordis subsea separation station in the North Sea which was installed last year. A leak detection monitor also is installed on the latest production template to be installed on the same operator’s Vigdis field this spring.

Next Page

Page 1 of 2